Show simple item record

COMPORTAMIENTO DE COMPRESIÓN AXIAL UNI DE CILINDROS DE CONCRETO DE CLAY EXPANDIDO CONFINADOS POR TUBO DE ACERO PERFORADO Y ENVOLVIENDO GFRP

dc.creatorMunish, Sathia
dc.creatorRamalingam, Vijayalakshmi
dc.creatorSrinivasan, Ramanagopal
dc.creatorGopinath, Vikram
dc.creatorRamanareddy, Yuvarani
dc.creatorRamanareddy, Yuvalatha
dc.date2020-12-25
dc.identifierhttp://revistadelaconstruccion.uc.cl/index.php/RDLC/article/view/rdlc.19.3.200
dc.identifier10.7764/rdlc.19.3.200-212
dc.descriptionEste estudio presenta la investigación experimental llevada a cabo en una columna de hormigón de arcilla expandida confinada por tubo de acero perforado reforzado por láminas de polímero reforzado con fibra de vidrio (GFRP) bajo compresión uniaxial. Se consideraron dos parámetros para la investigación experimental: El diámetro del tubo de acero perforado (5 mm y 10 mm) y el número de capas de envoltura GFRP (1,2, 3 y 4 capas). El comportamiento de compresión de la columna confinada de acero perforado se comparó con la columna de hormigón encerrada de tubo GFRP y la columna de hormigón encerrada de tubo de acero liso. Se discutió el efecto del diámetro de perforación y las capas GFRP, en el patrón de falla, la respuesta de tensión-deformación unitaria y la ductilidad de la columna. A partir de este estudio, se puede concluir que el envoltorio GFRP y el tubo de acero perforado ejercen todo el potencial para mejorar el comportamiento de compresión de la columna de hormigón agregado de arcilla expandida. El modo de falla de la columna de tubo de acero perforado envuelto GFRP era dúctil en la naturaleza. La falla comenzó con la ruptura de las capas de GFRP seguidas de la producción de tubo de acero perforado y finalmente la trituración de hormigón central.  El envoltorio GFRP proporciona resistencia a la tracción adicional a la columna y al tubo de acero perforado con su comportamiento plástico elasto mejora el comportamiento previo y posterior al pico de la columna. Se observó un mejor rendimiento de ductilidad en la columna con un mayor número de envoltura y columna GFRP con perforación de 10 mm de diámetro.en-US
dc.descriptionThis study presents the experimental investigation carried out on an Expanded Clay Aggregate concrete column confined by perforated steel tube strengthened by Glass Fiber Reinforced Polymer (GFRP) sheets under uniaxial compression. Two parameters were considered for the experimental investigation: The diameter of the perforated steel tube (5 mm and 10 mm) and number of layers of GFRP wrapping (1,2, 3 and 4 layers). The compression behavior of perforated steel confined column was compared with GFRP tube encased concrete column and plain steel tube encased concrete column. The effect of perforation diameter and GFRP layers, on the failure pattern, stress-strain response, and ductility of the column were discussed. From this study, it can be concluded that the GFRP wrapping and perforated steel tube exerts the full potential to enhance the compression behaviour of expanded clay aggregate concrete column. The failure mode of GFRP wrapped perforated steel tube column was ductile in nature. The failure started with the rupture of GFRP layers followed by yielding of perforated steel tube and finally crushing of core concrete.  The GFRP wrapping provides additional tensile strength to the column and the perforated steel tube with its elasto plastic behaviour enhances the pre-cracking and post peak behaviour of the column. Better ductility performance was observed in the column with a greater number of GFRP wrapping and column with 10 mm diameter perforation.es-ES
dc.formatapplication/pdf
dc.languageeng
dc.publisherEscuela de Construcción Civil de la Pontificia Universidad Católica de Chileen-US
dc.relationhttp://revistadelaconstruccion.uc.cl/index.php/RDLC/article/view/rdlc.19.3.200/21477
dc.rightsCopyright (c) 2020 Vijayalakshmi Ramalingam, Ramanagopal Srinivasan, Vikram Gopinath, Yuvarani Ramanareddy, Yuvalatha Ramanareddyen-US
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0en-US
dc.sourceRevista de la Construcción. Journal of Construction; Vol. 19 No. 3 (2020): Revista de la Construcción. Journal of Construction; 200-212en-US
dc.source0718-915X
dc.subjecthormigón LECA, tubo de acero perforado, envoltura GFRP, columna confinadaes-ES
dc.subjectLECA concrete, perforated steel tube, GFRP wrapping, Confined columnen-US
dc.titleUni axial compression behaviour of lightweight expanded clay aggregate concrete cylinders confined by perforated steel tube and GFRP wrappingen-US
dc.titleCOMPORTAMIENTO DE COMPRESIÓN AXIAL UNI DE CILINDROS DE CONCRETO DE CLAY EXPANDIDO CONFINADOS POR TUBO DE ACERO PERFORADO Y ENVOLVIENDO GFRPes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeresarchearticleen-US


This item appears in the following Collection(s)

Show simple item record