Show simple item record

Glazed curtain walls: Thermal transmitance calculation

dc.creatorde Gastines, Maureen
dc.creatorPattini, Andrea
dc.date2021-06-30
dc.identifierhttps://revistas.ubiobio.cl/index.php/RHS/article/view/4673
dc.identifier10.22320/07190700.2021.11.01.01
dc.descriptionGlazing is one of the dominant features of modern and contemporary architecture. This envelope design may have a great impact on operational energy demand of buildings. In this work, glazed façade systems available in Argentina are analyzed, with the purpose of determining the associated thermal transmittance ranges, in terms of the profiles’ design, the type of glazing and the size of glass panes. First, by using bidimensional numerical calculation, the impact of several profile design parameters on thermal transmittance is studied, highlighting the relevance of glazing fixing methods, to then calculate the thermal transmittance of the entire facade. The results indicate that the thermal transmittance value of glazed facades, mainly depends on the transmittance of the glass used, and exceeds this by 24% on average.en-US
dc.descriptionLa piel de vidrio es uno de los elementos dominantes de la arquitectura moderna y contemporánea. Este diseño de envolvente puede influir significativamente en la demanda de energía operativa de los edificios. En este trabajo, se analizan los sistemas de fachada de piel de vidrio disponibles en Argentina, con el objetivo de determinar los rangos de transmitancia térmica asociados, en función del diseño de perfiles, del tipo de vidriado y de las dimensiones de los paños vidriados. Inicialmente, se estudia mediante cálculo numérico bidimensional el impacto de varios parámetros de diseño de los perfiles sobre la transmitancia térmica, destacando la relevancia del modo de fijación del vidriado, para luego calcular la transmitancia térmica de las fachadas completas. Los resultados indican que el valor de transmitancia térmica de las fachadas de piel de vidrio depende principalmente de la transmitancia del vidriado empleado, y supera la misma en un 24%, en promedio.es-ES
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languagespa
dc.languageeng
dc.publisherUniversidad del Bío-Bío, Chilees-ES
dc.relationhttps://revistas.ubiobio.cl/index.php/RHS/article/view/4673/4040
dc.relationhttps://revistas.ubiobio.cl/index.php/RHS/article/view/4673/4041
dc.rightsDerechos de autor 2021 Maureen de Gastines, Andrea Pattinies-ES
dc.rightshttps://creativecommons.org/licenses/by-sa/4.0/deed.enes-ES
dc.sourceHábitat Sustentable; V.11, N.1 (2021): Junio 2021; 08 - 19es-ES
dc.sourceSustainable Habitat; V.11, N.1 (2021): June 2021; 08 - 19en-US
dc.sourceHábitat Sustentable; V.11, N.1 (2021): Junho de 2021; 08 - 19pt-PT
dc.source0719-0700
dc.subjectfachadases-ES
dc.subjectpiel de vidrioes-ES
dc.subjectíndiceses-ES
dc.subjectsistemas constructivoses-ES
dc.subjectfaçadesen-US
dc.subjectglazingen-US
dc.subjectindicesen-US
dc.subjectconstruction systemsen-US
dc.titleFachadas vidriadas: cálculo de transmitancia térmicaes-ES
dc.titleGlazed curtain walls: Thermal transmitance calculationen-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeArtículo revisado por pareses-ES


This item appears in the following Collection(s)