UTILIDAD DEL DISPOSITIVO DE POTENCIACIÓN DEL ESFÍNTER ESOFÁGICO DISTAL (LINX®) PARA PACIENTES CON REFLUJO GASTROESOFÁGICO
Usefulness of the distal esophageal sphincter enhancement device (LINX®) for patients with gastroesophageal reflux
dc.contributor | es-ES | |
dc.contributor | en-US | |
dc.creator | Gaete Letelier, Deycies Ivonne | |
dc.creator | Carreño Manríquez, Bárbara Sofía | |
dc.creator | Csendes Juhasz, Attila | |
dc.creator | Lanzarini Sobrevia, Enrique | |
dc.date | 2021-09-10 | |
dc.date.accessioned | 2021-10-04T14:55:16Z | |
dc.date.available | 2021-10-04T14:55:16Z | |
dc.identifier | https://www.revistacirugia.cl/index.php/revistacirugia/article/view/1116 | |
dc.identifier | 10.35687/s2452-454920210051116 | |
dc.identifier.uri | https://revistaschilenas.uchile.cl/handle/2250/176686 | |
dc.description | La fundoplicatura de Nissen laparoscópica (FNL) es el gold standard del tratamiento quirúrgico de pacientes con reflujo gastroesofágico patológico (RGE), con perfil de seguridad y resultados a largo plazo satisfactorios en un 80%. En la última década, se ha propuesto el uso de un dispositivo de potenciación del esfínter esofágico inferior (MSA) comercializado como LINX® (de Ethicon, Johnson & Johnson), como alternativa a la cirugía antirreflujo. El dispositivo consiste en una cadena expansible de cuentas de titanio con un núcleo magnético diseñadas para aumentar el tono del esfínter esofágico inferior (EEI) y evitar su relajación inadecuada. Los resultados preliminares han sido alentadores, sin embargo, no está exento de complicaciones. Las indicaciones más aceptadas son: RGE con motilidad esofágica normal y sin esofagitis erosiva, hernia hiatal < 3 cm, IMC <35 kg/m2, y, pacientes sin cirugías gastroesofágicas previas. Se instala por vía laparoscópica. Los efectos adversos más importantes son: disfagia con necesidad de dilataciones endoscópicas, y, retiro del dispositivo, entre 1 y 7% a los 2,5 años. La mayoría de los estudios tienen limitaciones metodológicas, conflictos de interés, falta de resultados objetivos y seguimientos a largo plazo, impidiendo llegar a conclusiones extrapolables respecto a la eficacia del MSA. | es-ES |
dc.description | Laparoscopic Nissen Fundoplication (LNF) is the gold standard of surgical treatment for patients with Gastroesophageal Reflux Disease (GER), with safety profile and long term results satisfactory in 80%. In the last decade, the use of a Lower Esophageal Sphincter Enhancement Device (LESD), marketed as LINX® (from Ethicon, Johnson & Johnson), has been proposed as an alternative to Anti-Reflux Surgery. The device consists of an expandable chain of titanium beads with a magnetic core designed to increase the tone of the lower esophageal sphincter (LES) and prevent its improper relaxation. Preliminary results have been encouraging; however, it is not without complications. The most accepted indications are: GER with normal esophageal motility and without erosive esophagitis, hiatal hernia < 3 cm, BMI < 35 kg/m2, and patients without previous gastroesophageal surgeries. It is installed by laparoscopy. The most important adverse effects are: dysphagia with the need for endoscopic dilations, and, removal of the device, between 1 and 7% at 2.5 years. Most of the studies have methodological limitations, conflicts of interest, lack of objective results and long-term follow-up, preventing the reaching of extrapolable conclusions regarding the efficacy of MSA. | en-US |
dc.format | application/pdf | |
dc.language | spa | |
dc.publisher | Sociedad Chilena de Cirugía | es-ES |
dc.relation | https://www.revistacirugia.cl/index.php/revistacirugia/article/view/1116/531 | |
dc.relation | https://www.revistacirugia.cl/index.php/revistacirugia/article/downloadSuppFile/1116/1770 | |
dc.relation | https://www.revistacirugia.cl/index.php/revistacirugia/article/downloadSuppFile/1116/1893 | |
dc.rights | Copyright (c) 2021 Deycies Ivonne Gaete Letelier, Bárbara Sofía Carreño Manríquez, Attila Csendes Juhasz, Enrique Lanzarini Sobrevia | es-ES |
dc.rights | https://creativecommons.org/licenses/by-sa/4.0 | es-ES |
dc.source | Revista de Cirugia; Vol. 73, Núm. 5 (2021) | en-US |
dc.source | Revista de Cirugía; Vol. 73, Núm. 5 (2021) | es-ES |
dc.source | 2452-4549 | |
dc.source | 2452-4557 | |
dc.subject | LINX; reflujo gastroesofágico; fundoplicatura | es-ES |
dc.subject | LINX; gastroesophageal reflux; fundoplication | en-US |
dc.title | UTILIDAD DEL DISPOSITIVO DE POTENCIACIÓN DEL ESFÍNTER ESOFÁGICO DISTAL (LINX®) PARA PACIENTES CON REFLUJO GASTROESOFÁGICO | es-ES |
dc.title | Usefulness of the distal esophageal sphincter enhancement device (LINX®) for patients with gastroesophageal reflux | en-US |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dc.type | es-ES | |
dc.type | Artículo de Revisión | es-ES |
dc.type | en-US | |
dc.type | en-US |
This item appears in the following Collection(s)
-
Revista de Cirugía
[0-9]{2}