• Journals
  • Discipline
  • Indexed
  • Institutions
  • About
JavaScript is disabled for your browser. Some features of this site may not work without it.
View Item 
  •   Home
  • Pontificia Universidad Católica de Chile
  • Revista Ingeniería de Construcción
  • View Item
  •   Home
  • Pontificia Universidad Católica de Chile
  • Revista Ingeniería de Construcción
  • View Item

CONCRETO ESTRUCTURAL MODIFICADO CON CAL DE CONCHAS DE ABANICO

STRUCTURAL CONCRETE MODIFIED WITH SCALLOP SHELL LIME

Author
Mauricio Villarrial, Ronal Alex

Farfan Cordova, Marlon Gaston

Full text
https://www.ricuc.cl/index.php/ric/article/view/1023
10.4067/RIC.00010.21
Abstract
La presente investigación se realizó con la finalidad de determinar el efecto de la cal de conchas de abanico (CCA) en la resistencia a compresión del concreto elaborado con cemento Portland tipo Ico y agregados naturales de una cantera; se adicionó CCA en porcentajes de 3%, 4% y 5%. Se determinaron las características físico – mecánicas de los agregados según la norma N.T.P. 400.037/ASTM C22 y se realizó el diseño de mezcla por el método ACI. Se utilizó la CCA por contener altos contenidos de calcio en la valva. Se elaboraron y curaron los testigos de concreto estándar (concreto patrón) y con la adición de 3%, 4% y 5% de CCA (339.0183/ASTM C192M) para ser analizados a los 7, 14 y 28 días de curado. Los resultados mostraron que la resistencia a compresión a los 28 días fue de 242.63 kg/cm2 al adicionar 3% de CCA, incrementándose con respecto al testigo patrón en un 16%. Para la adición de 4% de CCA la resistencia máxima alcanzada fue de 245.25 kg/cm2, y con 5% alcanzó una resistencia de 261.17 kg/cm2, incrementándose en 24%. Se concluye que la CCA tiene efecto positivo en el incremento de la resistencia del concreto, mostrándose que el porcentaje con mayor incidencia es el de 5%.
 
This research was conducted to determine the effect of the scallop shell lime (SSL) on the compressive strength of concrete made with Portland cement type Ico and natural aggregates from a quarry, where SSL was added at 3%, 4% and 5%. The physical and mechanical characteristics of the aggregates were determined based on the N.T.P. 400.037/ASTM C22 standard, and the mix design was carried out through the ACI method. The SSL was used due to the high calcium content present in the valve. Standard concrete controls were prepared and cured by adding 3%, 4% and 5% SSL (339.0183/ASTM C192M), which were analyzed at 7, 14 and 28 days of curing. The results showed that the compressive strength at 28 days was 242.63 kg/cm2 when 3% SSL was added, increasing with respect to the standard control by 16%. With the addition of 4% SSL, the maximum strength reached was 245.25 kg/cm2, and with 5%, the compressive strength reached was 261.17 kg/cm2, increasing by 24%. In conclusion, the SSL positively affects the increase of concrete strength, and the percentage with the highest incidence is 5%.
 
Metadata
Show full item record
Discipline
Artes, Arquitectura y UrbanismoCiencias Agrarias, Forestales y VeterinariasCiencias Exactas y NaturalesCiencias SocialesDerechoEconomía y AdministraciónFilosofía y HumanidadesIngenieríaMedicinaMultidisciplinarias
Institutions
Universidad de ChileUniversidad Católica de ChileUniversidad de Santiago de ChileUniversidad de ConcepciónUniversidad Austral de ChileUniversidad Católica de ValparaísoUniversidad del Bio BioUniversidad de ValparaísoUniversidad Católica del Nortemore

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister
Dirección de Servicios de Información y Bibliotecas (SISIB) - Universidad de Chile
© 2019 Dspace - Modificado por SISIB