dc.descriptionThis article describes and proposes a model of the force versus elongation behaviour of asymmetrical connections prone to bolt failure when subjected to quasi-static axial load. 14 connections were assembled with one bolt varying the distance from the bolt to the edge of the clamped zone, and 14 connections were assembled with two bolts varying the distance between bolts. Results show that the axial force versus elongation behaviour of the connection is approximately trilinear, that while the connection stiffness is not sensitive to the bolt location in the clamped zone, the plastic elongation of the connection is. The model shows that the stiffness of the asymmetrical connection can be predicted from the stiffness of the connection components assessed by means of spring elements or beam elements, and that the load capacity of the connection can be predicted using the dry friction theory of Coulomb and the shear bolt capacity.en-US
dc.descriptionEl Este artículo describe y propone un modelo del comportamiento fuerza contra elongación de conexiones metálicas asimétricas susceptible a falla de pernos cuando sometidas a carga axial cuasi-estática. 14 conexiones se ensamblaron con un perno variando la distancia desde el perno al borde de la zona de unión de las platinas y 14 conexiones se ensamblaron con dos pernos variando la distancia entre pernos. Los resultados experimentales muestran que el comportamiento fuerza axial contra elongación de la conexión es aproximadamente trilineal y que mientras la rigidez de la conexión no es sensible a la localización de los pernos en la zona de unión de las platinas; la elongación plástica de la conexión si lo es. El modelo muestra que la rigidez de la conexión asimétrica se puede predecir evaluando la rigidez de los componentes de la conexión usando elementos de resorte y viga y que la capacidad de carga de la conexión se puede predecir con base en la teoría de la fricción seca de Coulomb y la capacidad a corte de los pernoses-ES
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languagespa
dc.languageeng
dc.publisherPontificia Universidad Católica de Chileen-US
dc.relationhttps://www.ricuc.cl/index.php/ric/article/view/678/PDF%20SPANISH
dc.relationhttps://www.ricuc.cl/index.php/ric/article/view/678/PDF%20ENGLISH
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/184
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/185
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/186
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/187
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/188
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/189
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/190
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/191
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/192
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/193
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/194
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/195
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/196
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/197
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/198
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/199
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/200
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/201
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/202
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/203
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/204
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/205
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/206
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/207
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/208
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/209
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/210
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/211
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/212
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/213
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/214
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/215
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/216
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/217
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/218
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/219
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/220
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/221
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/222
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/223
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/224
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/225
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/226
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/227
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/228
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/678/229
dc.rightsCopyright (c) 2019 Revista Ingeniería de Construcciónen-US
dc.rightshttp://creativecommons.org/licenses/by/4.0en-US
dc.sourceRevista Ingeniería de Construcción; Vol 34, No 2 (2019); 193-204es-ES
dc.sourceRevista Ingeniería de Construcción; Vol 34, No 2 (2019); 193-204en-US
dc.source0718-5073
dc.source0716-2952
dc.subjecten-US
dc.subjectSteel connection, Asymmetrical connection, Distance between bolts, Distance from bolt to edge, Asymmetrical connection stiffnessen-US
dc.subjectIngeniería civil; Estructuras metálicas; conexiones metálicases-ES
dc.subjectConexión metálica; Conexión asimétrica; Distancia entre pernos; Distancia desde el perno al borde; Rigidez de conexión asimétricaes-ES
dc.titleExperimental and theoretical characterization of steel asymmetrical connections prone to bolt failureen-US
dc.titleCaracterización experimental y teórica de conexiones metálicas asimétricas susceptibles a falla de pernoses-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeen-US
dc.typeArtículo revisado por pareses-ES


This item appears in the following Collection(s)

Show simple item record