Show simple item record

Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire

dc.contributores-ES
dc.contributoren-US
dc.creatorDíaz, I.
dc.creatorLarrúa, R.
dc.creatorWainshtok, H.
dc.creatorMackchaser, M.
dc.date2021-04-30
dc.date.accessioned2022-06-01T16:14:38Z
dc.date.available2022-06-01T16:14:38Z
dc.identifierhttps://www.ricuc.cl/index.php/ric/article/view/1176
dc.identifier10.4067/S0718-50732021000100097
dc.identifier.urihttps://revistaschilenas.uchile.cl/handle/2250/183314
dc.descriptionLa importancia del diseño de estructuras expuestas al fuego, junto con la incertidumbre en el comportamiento y resistencia de las estructuras de hormigón armado con barras de polímeros reforzados con fibras (PRF) a elevadas temperaturas, evidencian la necesidad de más investigaciones en este sentido. Aun cuando existen estudios dirigidos a la evaluación de los esfuerzos resistentes de flexión y cortante en situaciones de incendio en estos elementos, no existen normas o regulaciones que especifiquen procedimientos para ello. En este trabajo se proponen métodos para el cálculo de la resistencia al corte en vigas de hormigón armado con PRF, de sección rectangular, a partir de la degradación de las propiedades de los materiales y/o la sección reducida de hormigón, según lo recomendado por (Diab, 2014), el Eurocódigo 2 (EN-1992-1-2, 2004) y (Saafi, 2002). Partiendo del análisis térmico realizado con el programa Super Tempcalc, estos procedimientos se aplicaron en 13 vigas, con distintas dimensiones y armados, sometidas al fuego estándar de la norma ISO-834 (2000) en tres caras, obteniéndose las curvas de degradación de la capacidad a cortante para cada caso. Los resultados demuestran que las diferencias entre los valores de resistencia al corte fueron muy pequeñaspara todo el tiempo de exposición al fuego considerado.es-ES
dc.descriptionThe importance of structural design under fire conditions, together with the uncertainty in the behavior and resistance of reinforced concrete structures with fiber-reinforced polymer bars (FRP) at high temperatures, reveal the need for more research along these lines. Although there are studies evaluating the flexural and shear strength of elements exposed to fire, there are no standards nor regulations specifying the procedures thereto. This work proposes methods to calculate shear strength in FRP-reinforced concrete beams, with rectangular cross-section, based on the degradation of the properties of the materials and/or the reduced concrete cross-section, as recommended by (Diab, 2014), Eurocode 2 (EN-1992-1-2, 2004) and (Saafi, 2002). In accordance with the thermal analysis executed with the Super Tempcalc software, these procedures were applied to 13 beams of different dimensions and reinforcements, subjected to standard fire of the ISO-834 standard on three sides, thereby obtaining the shear capacity degradation curves for each case. The results show that the differences between the shear strength values were very small throughout the total fire exposure time.en-US
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languagespa
dc.languageeng
dc.publisherPontificia Universidad Católica de Chileen-US
dc.relationhttps://www.ricuc.cl/index.php/ric/article/view/1176/PDF%20SPANISH
dc.relationhttps://www.ricuc.cl/index.php/ric/article/view/1176/PDF%20ENGLISH
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/1176/577
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/1176/578
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/1176/579
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/1176/580
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/1176/581
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/1176/582
dc.relationhttps://www.ricuc.cl/index.php/ric/article/downloadSuppFile/1176/583
dc.rightsCopyright (c) 2021 Revista Ingeniería de Construcciónen-US
dc.rightshttp://creativecommons.org/licenses/by/4.0en-US
dc.sourceRevista Ingeniería de Construcción; Vol 36, No 1 (2021); 97-106es-ES
dc.sourceRevista Ingeniería de Construcción; Vol 36, No 1 (2021); 97-106en-US
dc.source0718-5073
dc.source0716-2952
dc.subjectDiseño de estructuras; diseño con polímeroses-ES
dc.subjectVIga, hormigón armado, cortante, fuego, polímeros reforzados con fibras (PRF)es-ES
dc.subjecten-US
dc.subjectBeam, reinforced concrete, shear, fire, fiber-reinforced polymer (FRP)en-US
dc.titleMétodos simplificados para la determinación de la resistencia al corte en vigas de hormigón armado con polímeros reforzados con fibras expuestas al fuegoes-ES
dc.titleSimplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fireen-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeen-US
dc.typeArtículo revisado por pareses-ES


This item appears in the following Collection(s)

Show simple item record