Show simple item record

dc.creatorRojas Espinoza, Gerson
dc.creatorOrtiz Iribarren, Oscar
dc.date2014-12-24
dc.date.accessioned2023-03-13T20:57:48Z
dc.date.available2023-03-13T20:57:48Z
dc.identifierhttps://revistas.ubiobio.cl/index.php/MCT/article/view/1415
dc.identifier.urihttps://revistaschilenas.uchile.cl/handle/2250/223820
dc.descriptionEl presente estudio tuvo por objetivo identifi car el cilindro nudoso en imágenes de tomografía computarizada (TC) de trozas podadas de Pinus radiata, utilizando un algoritmo de clasifi cación su-pervisada. El proceso de clasifi cación fue necesario para identifi car y separar el cilindro nudoso de la zona libre de defectos y nudos.  Diez trozas podadas de Pinus radiata fueron escaneadas en un escáner médico de rayos X, multi-slice, de marca Philips, donde las imágenes TC resultantes fueron obtenidas cada 5 mm. Un total de 270  imágenes TC fueron  clasifi cadas con el clasifi cador de máxima verosimi-litud, y los mapas temáticos resultantes, fueron fi ltrados con un fi ltro median de 7 x 7. Luego, 90 mapas temáticos fueron seleccionados y utilizados para evaluar la precisión del proceso de clasifi cación. Para ello,  la matriz de confusión e índice kappa fueron obtenidas utilizando una muestra de 70 pixeles selec-cionados aleatoriamente de cada mapa temático. Un valor de precisión de 98,5 % fue obtenido para la identifi cación del cilindro nudoso y de 92,5 % para la precisión global de la clasifi cación. El valor Ka-ppa fue de 0,730, lo cual indica que existe un fuerte grado de conformidad entre los datos de referencia y el procedimiento de clasifi cación. Estos resultados sugieren que es factible aplicar el procedimiento de clasifi cación para identifi car las características internas de trozas podadas de Pinus radiata.This study aims to identify the defective core on computed tomography images (CT) of pruned radiata pine logs, using an algorithm of supervised classifi cation. The classifi cation process was requi-red to identify and separate the defective core from the free defect part and knots. Ten pruned radiata pine logs were scanned into a medical X-ray multi-slice Philips scanner and the resulting CT images at 5 mm. were obtained. A total amount of 270 CT images were classifi ed under with the maximum likelihood classifi er and the resulting thematic maps were fi ltered with a median fi lter of 7 x 7. Then, 90 thematic maps were selected and used to assess the accuracy of the classifi cation process. To ac-complish this, the Confusion Matrix and Kappa statistic were obtained using a sample consisting of 70 randomly selected pixels of each thematic map. An accuracy value of 98.5% was obtained for the defective core identifi cation and 92.5 % for the overall accuracy of the classifi cation. The Kappa value was 0.730 indicating a strong agreement between the ground truth and the classifi cation procedure. These results suggest that it is feasible to implement the classifi cation procedure for identifying the internal characteristics of pruned radiata pine logs.es-ES
dc.formatapplication/pdf
dc.languagespa
dc.publisherUniversidad del Bio-Bioen-US
dc.relationhttps://revistas.ubiobio.cl/index.php/MCT/article/view/1415/1362
dc.rightsCopyright (c) 2015 Gerson Rojas Espinoza, Oscar Ortiz Iribarrenen-US
dc.sourceMaderas-Cienc Tecnol; Vol. 11 No. 2 (2009); 117-127en-US
dc.sourceMaderas-Cienc Tecnol; Vol. 11 Núm. 2 (2009); 117-127es-ES
dc.source0718-221X
dc.source0717-3644
dc.subjectCilindro nudosoes-ES
dc.subjectrayos Xes-ES
dc.subjectmáxima verosimilitudes-ES
dc.subjectmatriz de confusiónes-ES
dc.subjectPinus radiataes-ES
dc.subjectDefective Corees-ES
dc.subjectX-rayes-ES
dc.subjectMaximum Likelihoodes-ES
dc.subjectConfusion Matrixes-ES
dc.subjectradiata pine.es-ES
dc.titleIdentificacion del cilindro nudoso en imagenes tc de trozas podadas de Pinus radiata utilizando el clasificador de maxima verosimilitudes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion


This item appears in the following Collection(s)

Show simple item record