Show simple item record

Design of a dynamometer for the objective evaluation of the motive muscles of the arm

dc.creatorBisio, Lucas
dc.creatorGutierrez, Gastón
dc.creatorMarquez, Aníbal
dc.creatorDe Falco, Rosanna
dc.creatorPorro, Sandra
dc.creatorCisilino, Adrián P.
dc.date2008-01-01
dc.date.accessioned2019-04-15T13:45:59Z
dc.date.available2019-04-15T13:45:59Z
dc.identifierhttps://revistaterapiaocupacional.uchile.cl/index.php/RTO/article/view/77
dc.identifier10.5354/0719-5346.2008.77
dc.identifier.urihttp://revistaschilenas.uchile.cl/handle/2250/32530
dc.descriptionLas pruebas de fuerza muscular proporcionan información fundamental para el diagnóstico diferencial, pronóstico y tratamiento de los trastornos neuro-musculares y músculo-esqueléticos en el miembro superior. Las evaluaciones utilizadas en la actualidad se basan en métodos manuales que utilizan escalas de registro ambiguas que dependen más de la capacidad muscular del examinador que la del evaluado. Con la finalidad de disponer de una metodología objetiva para valoración de la capacidad funcional del miembro superior se presenta en este trabajo el diseño de un dinamómetro para la medición instrumentada de las fuerzas de los músculos motores primarios del brazo. El diseño propuesto resulta en una aparatología discreta, portátil y con adquisición computarizada de los datos. Al mismo tiempo, posibilita el necesario contacto entre el examinador   y el evaluado para realizar las maniobras de fijación, estabilización y verificación de tonicidad muscular.es-ES
dc.descriptionMuscle force evaluation provides fundamental information for the diagnosis,prediction and treatment of neuro-muscular and muscle-skeletal disorders in theupper limb. Current evaluation techniques are based on manual methods withambiguous valuation scales that depend more of the muscular capacity of theexaminer than that of the person under evaluation.It is presented in this work the design of a dynamometer for the evaluation of theforces exerted by the motive muscles of the arm. The proposed device aims to thedevelopment of an objective methodology for the assessment of the functionalcapacity of the upper limb. The design consists in a simple portable device withan automated data acquisition system. At the same time, it allows the necessarycontact between the examiner and the evaluated person during the maneuvers offixation, stabilization and muscle tone verification.en-US
dc.formatapplication/pdf
dc.languagespa
dc.publisherUniversidad de Chile. Facultad de Medicinaes-ES
dc.relationhttps://revistaterapiaocupacional.uchile.cl/index.php/RTO/article/view/77/61
dc.sourceRevista Chilena de Terapia Ocupacional; Núm. 8 (2008): Diciembre; Pág. 71 - 78es-ES
dc.sourceRevista Chilena de Terapia Ocupacional; Núm. 8 (2008): Diciembre; Pág. 71 - 78pt-BR
dc.sourceRevue Chilien d'ergothérapie; Núm. 8 (2008): Diciembre; Pág. 71 - 78fr-CA
dc.source0719-5346
dc.source0717-6767
dc.titleDiseño de un dinamómetro para la evaluación objetiva de los músculos motores del brazoes-ES
dc.titleDesign of a dynamometer for the objective evaluation of the motive muscles of the armen-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeArtículo originales-ES


This item appears in the following Collection(s)

Show simple item record