Show simple item record

dc.creatorBlanchot,George
dc.creatorHervas,Luis
dc.creatorKierstead,Jim
dc.creatorLanni,Francesco
dc.creatorRescia,Sergio
dc.creatorVerdugo,Mauricio
dc.creatorPontt,Jorge
dc.creatorOlivares,Ricardo
dc.creatorRobles,Hernán
dc.creatorDíaz,Sergio
dc.date2008-06-01
dc.date.accessioned2019-04-24T21:27:43Z
dc.date.available2019-04-24T21:27:43Z
dc.identifierhttps://scielo.conicyt.cl/scielo.php?script=sci_arttext&pid=S0718-33052008000100015
dc.identifier.urihttp://revistaschilenas.uchile.cl/handle/2250/58403
dc.descriptionThe front-end electronics of the ATLAS Liquid Argon Calorimeter is powered by DC/DC converters nearby the front-end crates. They are fed by AC/DC converters located in a remote control room through long power cables. The stability of the power distribution scheme is compromised by the impedance of the long interconnection cable, and proper matching of the converters dynamic impedances is required. Also, the long power cable fed by a powerful AC/DC converter is a source of electromagnetic interferences in the experimental area. The optimal grounding and shielding configuration to minimize these EMI is discussed.
dc.formattext/html
dc.languageen
dc.publisherUniversidad de Tarapacá.
dc.relation10.4067/S0718-33052008000100015
dc.rightsinfo:eu-repo/semantics/openAccess
dc.sourceIngeniare. Revista chilena de ingeniería v.16 n.1 2008
dc.subjectElectromagnetic compatibility
dc.subjectDC power distribution system
dc.subjectstability
dc.subjectnoise propagation
dc.subjectEMI emissions
dc.titleELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETER


This item appears in the following Collection(s)

Show simple item record