dc.description | La presente investigación tuvo como objetivo principal evaluar el comportamiento de corrosión en vigas de concreto reforzado, por medio técnicas electroquímicas como la medición de Potenciales de Corrosión y Resistencia a la Polarización Lineal. Estas vigas son expuestas a ciclos de secado y saturación en agua potable y cloruro de sodio (NaCl) al 3.5%, ya que la técnica de Resistencia a la Polarización es la que actualmente se aplica para la evaluación de estructuras de concreto reforzado así como el efecto en el proceso corrosivo del refuerzo y el mecanismo de deterioro en las estructuras. La evaluación se realizó en vigas de concreto de 6” x 6” x 20”, reforzado con varillas de acero de 3/8” y estribos de 1/4” a cada 8” las cuales se dividieron en diferentes zonas protegidas con la finalidad de tener bien definidas las zonas susceptibles a la corrosión. Se realizaron en tres series, de seis vigas por cada tipo de aplicación: concreto simple, preoxidadas y preagrietadas la carga teórica permisible que resiste la sección propuesta se calcula con las fórmulas de la teoría elástica, así como un espécimen testigo, los potenciales de corrosión para la mayoría de las vigas presentaron una incertidumbre del fenómeno de corrosión para el cloruro de sodio (NaCl) de acuerdo con el criterio de evaluación que establece la Norma ASTM C876 y la velocidad de corrosión de las vigas expuestas en cloruro de sodio presentaron un grado de corrosión despreciable. | es-ES |
dc.description | The aim of this paper is the evaluation of the behavior of corrosion in reinforced concrete beams, by means of electrochemical techniques corrosion potentialmeasurements and Linear Polarization Resistance techniques. These beams are exposed to moisturizing and drying cycles with 3.5 % sodium chloride (NaCl)and drinkable water. Up to now, the Linear Polarization Resistance technique is the only that is applied for evaluating reinforced concrete structures andmeasuring the effect the reinforcement of corrosion and the deterioration mechanism of structures. The evaluation was affected in concrete of beams of 6”x 6” x 20”, reinforced with bars of 3/8” and stirrups of 1/4” to each 8”, which were divided in different areas protected with the purpose of having verydefined the susceptible areas to suffer corrosion.They were carried out in three series, of six beams for each type of application: plain concrete, prexiodedand preload, the theoretical permissible load that resist the proposal section is calculated with the formulas of the elastic theory, as well as a specimen witness, the corrosion potential, in most of the beams presented an uncertainty of the corrosion phenomenon for the sodium chloride (NaCl) according tothe establish to the ASTM C876 standard and the corrosion rate of the beams exposed in sodium chloride presented a moderate corrosion degree. | en-US |
dc.format | application/pdf | |
dc.format | application/pdf | |
dc.language | spa | |
dc.language | eng | |
dc.publisher | Pontificia Universidad Católica de Chile | en-US |
dc.relation | http://www.ricuc.cl/index.php/ric/article/view/136/pdf | |
dc.relation | http://www.ricuc.cl/index.php/ric/article/view/136/pdf_1 | |
dc.source | Revista Ingeniería de Construcción; Vol 19, No 1 (2004); 19-26 | es-ES |
dc.source | Revista Ingeniería de Construcción; Vol 19, No 1 (2004); 19-26 | en-US |
dc.source | 0718-5073 | |
dc.source | 0716-2952 | |
dc.subject | Corrosión; concreto reforzado; potencial de corrosión; resistencia a la polarización lineal; velocidad de corrosión. | es-ES |
dc.subject | Corrosion; reinforced concrete; corrosion potential; lineal polarization resistance; corrosion rate | en-US |
dc.title | Evaluación de la corrosión en vigas de concreto reforzado en presencia de agua potable y NaCl al 3.5% | es-ES |
dc.title | Evaluating of the corrosion in concrete of beams reinforced in the presence drinkable water and with NaCl 3.5% | en-US |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dc.type | en-US | |
dc.type | Artículo revisado por pares | es-ES |
This item appears in the following Collection(s)
-
Revista Ingeniería de Construcción
[0-9]{4}