Water hammer in a pipe network due to a fast valve closure
Golpe de ariete en una red de tuberías debido al cierre rápido de una válvula
Author
Twyman, J.
Abstract
Water hammer in pipe networks is a subject little discussed in the technical literature. This may be due to the belief that the network shape helps to reduce its impact, since the pressure waves would tend to subdivide as they propagate through the system pipes. In this article the water hammer is analysed in a pipe network due to the closure of a valve modelled how if it were of type butterfly, gate circular, gate square, ball, needle and globe. It is concluded that the extreme pressure values depend on the type of valve which it is being closed, and that the network shape is not a relevant factor that it helps to attenuate the transient pressures. El golpe de ariete en las redes de tuberías es un tema poco discutido en la literatura técnica. Esto puede deberse a la creencia de que la forma de la red ayuda a reducir su impacto, ya que las ondas de presión tienden a subdividirse a medida que se propagan a través de las tuberías del sistema. En este artículo, se analiza el golpe de ariete en una red de tuberías debido al cierre de una válvula modelada como si fuera de tipo mariposa, compuerta circular, compuerta cuadrada, bola, aguja y globo. Se concluye que los valores extremos de la presión dependen del tipo de válvula que se está cerrando, y que la forma de la red no es un factor relevante que ayude a atenuar las presiones transitorias.