Ensaye de muros de albañilería estructural construídos con bloques de hormigón y cuantía reducida de refuerzos

Cyclic tests of concrete masonry walls with reduced quantity of reinforcement

Author
Ogaz, Oscar

Astroza, Maximiliano

Sierra, Guillermo

Full text
http://www.ricuc.cl/index.php/ric/article/view/OGAZ
Abstract
En este trabajo se analiza el comportamiento de muros de albañilería construidos con bloques huecos de hormigón y con cuantía reducida de refuerzo, refuerzos que corresponden a las dos modalidades más utilizadas en el medio nacional, como son: la albañilería confinada y la albañilería armada. En particular se analizan los resultados obtenidos de los ensayos de cuatro muros de albañilería confinada y armada, los cuales son parte de un estudio experimental desarrollado para obtener información con la cual se pueda establecer las bases de diseño para viviendas de albañilería de uno y dos pisos. El comportamiento de los muros se analiza evaluando la capacidad resistente, la rigidez lateral inicial, la capacidad de deformación y de disipación de energía.
 
The results of an experimental study of two confined masonry walls and two reinforced masonry walls with reduced quantity of reinforcement are presented.The full scale walls were made of hollow concrete blocks and were tested with horizontal cyclic loads. The dimensions of the walls were 3650x2250 mmand the thickness of the walls was 140 mm. The cross-sectional area of horizontal reinforcement is 0.0003 times the gross-sectional area of the reinforcedmasonry wall. The cracking and damage patterns, strength and stiffness degradation and deterioration, energy dissipation capacity and displacement capacityafter the cracking are analyzed. The conclusions are useful for the seismic design of one and two stories masonry dwellings.
 
Metadata
Show full item record
Discipline
Artes, Arquitectura y UrbanismoCiencias Agrarias, Forestales y VeterinariasCiencias Exactas y NaturalesCiencias SocialesDerechoEconomía y AdministraciónFilosofía y HumanidadesIngenieríaMedicinaMultidisciplinarias
Institutions
Universidad de ChileUniversidad Católica de ChileUniversidad de Santiago de ChileUniversidad de ConcepciónUniversidad Austral de ChileUniversidad Católica de ValparaísoUniversidad del Bio BioUniversidad de ValparaísoUniversidad Católica del Nortemore

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister
Dirección de Servicios de Información y Bibliotecas (SISIB) - Universidad de Chile
© 2019 Dspace - Modificado por SISIB