Show simple item record

dc.contributoren-US
dc.creatorGómez-Rubiera, Enrique Larrumbide; Instituto Eduardo Torroja de Ciencias de la Construcción. Consejo Superior de Investigaciones Científicas Calle de Serrano Galvache, 4, 28033 Madrid (Spain)
dc.creatorSánchez-Torija, Jorge Gallego; Departamento de Construcción y Tecnología Arquitectónicas, Escuela Técnica Superior de Arquitectura, Universidad Politécnica de Madrid Avenida de Juan de Herrera 4, 28040 Madrid (Spain)
dc.creatorBedoya Frutos, César; Departamento de Construcción y Tecnología Arquitectónicas, Escuela Técnica Superior de Arquitectura, Universidad Politécnica de Madrid Avenida de Juan de Herrera 4, 28040 Madrid (Spain)
dc.date2019-04-26
dc.identifierhttp://revistadelaconstruccion.uc.cl/index.php/rdlc/article/view/1433
dc.descriptionDOI: 10.7764/RDLC.18.1.145An energy audit is a useful tool that sets out possibilities for improvement, optimization and energy saving. For the study of the thermal envelope, it is useful to use energy simulation tools that use suitably validated reference climates and simulation procedures. The results of the Unified Lider Calener Tool (HULC), and its subsequent processing of results, allow intervention priorities to be established aimed at aiding the energy manager of the building when proposing energy reform measures involving a degree of economic savings, so that the proposed investments allow a reasonable payback period. A teaching center has been chosen as a case study because presenting a tool that allows to save on energy consumption and quantify the payback terms of the investments is relevant. This paper quantifies the payback periods of the investments to be made to improve the thermal envelope of the building. To this end, the case study building was modeled and an economic analysis was carried out, which led to the conclusion that the most beneficial action is the replacement of the windows.   en-US
dc.formatapplication/pdf
dc.languageeng
dc.publisherPONTIFICIA UNIVERSIDAD CATOLICA DE CHILEen-US
dc.relationhttp://revistadelaconstruccion.uc.cl/index.php/rdlc/article/view/1433/387
dc.sourceRevista de la Construcción. Journal of Construction; Vol 18, No 1 (2019): Revista de la Construcción. Journal of Construction; 145-155en-US
dc.source0718-915X
dc.source0717-7925
dc.subjecten-US
dc.subjectenergy audit, refurbishment, energy optimization, window aperture, thermal envelopeen-US
dc.titleApplication of the energy audit methodology on the thermal envelope in a building for educational use in Madriden-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typePeer-reviewed Articleen-US


This item appears in the following Collection(s)

Show simple item record