• Journals
  • Discipline
  • Indexed
  • Institutions
  • About
JavaScript is disabled for your browser. Some features of this site may not work without it.
View Item 
  •   Home
  • Servicio Nacional de Geología y Minería
  • Andean Geology
  • View Item
  •   Home
  • Servicio Nacional de Geología y Minería
  • Andean Geology
  • View Item

La precipitacion torrencial del ano 2000 en Quebrada Chacarilla y el calculo de recarga al acuifero Pampa Tamarugal, norte de Chile.

The year 2000 storm event in the Quebrada Chacarilla and calculation of recharge to the Pampa Tamarugal aquifer.

Author
Houston, John

Full text
http://www.andeangeology.cl/index.php/revista1/article/view/V28n2-a02
10.5027/andgeoV28n2-a02
Abstract
Una importante crecida repentina tuvo lugar en la cuenca de captacion de Chacarilla en enero de 2000 como lo demuestran los depositos de corriente de lodo supra-ribera en disposicion regresiva. El caudal maximo se ha determinado en 450 (± 50) m3/s y es posible rastrear su origen hasta un evento de tormenta cuantificable en el Altiplano. Mas abajo, la crecida infiltro el abanico aluvial para recargar los acuiferos. Un pozo de monitoreo al pie del abanico mostro un aumento del nivel de agua debido a infiltracion de 0,45 m lo que representa un evento de recarga de 25 millones de m3. La tormenta que dio origen a esta recarga tiene un periodo de retorno de 4 anos, de modo que la recarga anual media es equivalente a ~200 l/s. La respuesta de la cuenca de captacion se ha establecido como no lineal con retroalimentacion positiva, de modo que eventos aun mas raros entregan una recarga proporcionalmente mayor. Las disminuciones del nivel de aguas subterraneas a largo plazo pueden deberse en parte a las fluctuaciones climaticas y las causas de dichas fluctuaciones son discutidas.
 
A major flash flood took place in the Chacarilla catchment in January 2000 as indicated by offlapping overbank mudflow deposits. The peak flood has been determined at 450 (± 50) m3/s and it is possible to trace the origin of this flood to a quantifiable storm event in the Altiplano. Downstream, the surface water flood infiltrated the alluvial fan to recharge groundwater aquifers. A monitoring well in the fan toe showed a water level rise due to infiltration of 0.45 m that can be translated into a recharge event of 25 million m3. The storm giving rise to this recharge has a return period of 4 years and so mean annual recharge is equivalent to ~200 l/s. The catchment response is shown to be non-linear with positive feedback, so that rarer events provide proportionately greater recharge. Long-term declines in groundwater level may be partly due to climatic fluctuations and the causes of such fluctuations are discussed.
 
Metadata
Show full item record
Discipline
Artes, Arquitectura y UrbanismoCiencias Agrarias, Forestales y VeterinariasCiencias Exactas y NaturalesCiencias SocialesDerechoEconomía y AdministraciónFilosofía y HumanidadesIngenieríaMedicinaMultidisciplinarias
Institutions
Universidad de ChileUniversidad Católica de ChileUniversidad de Santiago de ChileUniversidad de ConcepciónUniversidad Austral de ChileUniversidad Católica de ValparaísoUniversidad del Bio BioUniversidad de ValparaísoUniversidad Católica del Nortemore

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister
Dirección de Servicios de Información y Bibliotecas (SISIB) - Universidad de Chile
© 2019 Dspace - Modificado por SISIB