Show simple item record

dc.creatorPeinado-Guevara,Héctor
dc.creatorGreen-Ruíz,Carlos
dc.creatorHerrera-Barrientos,Jaime
dc.creatorEscolero-Fuentes,Oscar
dc.creatorDelgado-Rodríguez,Omar
dc.creatorBelmonte-Jiménez,Salvador
dc.creatorLadrón de Guevara,María
dc.date2012-04-01
dc.date.accessioned2019-05-17T13:11:36Z
dc.date.available2019-05-17T13:11:36Z
dc.identifierhttps://scielo.conicyt.cl/scielo.php?script=sci_arttext&pid=S0718-16202012000100020
dc.identifier.urihttps://revistaschilenas.uchile.cl/handle/2250/98041
dc.descriptionSoils in arid or semi-arid areas often have salinity problems, so the quality of irrigation water plays an important role in agricultural production. Groundwater quality analysis includes the determination of chloride ions, which are toxic to plants in high concentrations. A total of 1358 groundwater samples were collected and analyzed in the period 1980-2008. Water electrical conductivity [EC] and chloride ion concentration values were related by the linear equation [Cl-] = 4.928 EC (R> 0.94), to estimate the concentration of chloride ions as a function of the electrical conductivity of water in the study area. A geophysical survey was conducted through 34 Vertical Electrical Soundings (VESs) to calculate the water electrical conductivity from the interpretation of the apparent resistivity data. Twenty-nine VESs were used to relate the resistivity of the saturated formation (Ro) with that for the groundwater (Rw) by the linear equation Rw = 0.427 Ro + 1.987. Then, EC was estimated as the inverse of Rw. Finally, the chloride ion concentration was determined by the equation mentioned above. Following the same procedure for the five remaining VESs, which were acquired in places where there are no wells, the chloride ion concentration and the electrical resistivity of the saturated formation (Ro) and groundwater (Rw and its inverse EC) were obtained without requiring a destructive technique.
dc.formattext/html
dc.languageen
dc.publisherPontificia Universidad Católica de Chile. Facultad de Agronomía e Ingeniería Forestal
dc.relation10.4067/S0718-16202012000100020
dc.rightsinfo:eu-repo/semantics/openAccess
dc.sourceCiencia e investigación agraria v.39 n.1 2012
dc.subjectArchie's Law
dc.subjectchlorides
dc.subjectelectrical conductivity
dc.subjectresistivity
dc.subjectvertical electrical sounding (VES)
dc.titleRelación entre concentración de cloruros y conductividad eléctrica en aguas subterráneas y su estimación a partir de Sondeos Eléctricos Verticales (SEV) en Guasave, Sinaloa, México