Design of stud connections in steel – concrete composite structures in fire situation

dc.contributorCAPES (Coordinación para el Perfeccionamiento del Personal de Nivel Superior, Brasil)es-ES
dc.contributoren-US
dc.creatorLarrúa, Yisel
dc.creatorLarrua, Rafael
dc.creatorP. Silva, Valdir
dc.date2015-04-30
dc.date.accessioned2022-04-12T11:29:14Z
dc.date.available2022-04-12T11:29:14Z
dc.identifierhttps://www.ricuc.cl/index.php/ric/article/view/540
dc.identifier10.4067/S0718-50732015000100004
dc.identifier.urihttps://revistaschilenas.uchile.cl/handle/2250/181233
dc.descriptionEn el trabajo se aborda el estudio de los factores que inciden en la resistencia, en situación de incendio, de las conexiones tipo perno en estructuras compuestas hormigón–acero con tipología de viga y losa maciza. Se realiza el diseño del experimento, la modelación térmica de los especímenes del ensayo push-out y el análisis de significación de diferentes parámetros en las relaciones de temperatura en secciones compuestas con vigas sin revestimiento y con revestimiento contra incendio. Por último, se proponen las temperaturas a considerar en el hormigón y el conector, expresadas como porcientos de la temperatura en el ala del perfil, para determinar los factores de reducción de la resistencia de la conexión en situación de incendio. Los resultados demuestran que los porcientos propuestos por EN 1994-1-2 (2005) para determinar la temperatura en el hormigón y el conector a partir de la temperatura en el ala no son válidos para todas las situaciones de diseño dentro del alcance del código.Rev. ing. constr. [online]. 2015, vol.30, n.1, pp. 39-52. ISSN 0718-5073.  http://dx.doi.org/10.4067/S0718-50732015000100004es-ES
dc.descriptionThis work studies the factors that impact on the fire resistance of stud connections in steel–concrete composite structures, considering beams with solid slab. The design of the experiment, the thermal modeling of the push-out specimens, with or without fire protection material, and the analysis of the significance of the different parameters in the temperature relationships are carried out. Finally, the temperatures that should be considered in the concrete and the connector, expressed as percentages of the steel flange temperature, are proposed in order to determine the reduction factors of the connection resistance in fire situation. The results demonstrate that the percentages proposed in EN 1994-1-2 (2005) to determine the temperature in the concrete and the connector, based on the temperature in the steel flange, are not valid for all design situations within the scope of the code.Rev. ing. constr. [online]. 2015, vol.30, n.1, pp. 39-52. ISSN 0718-5073. http://dx.doi.org/10.4067/S0718-50732015000100004en-US
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.formattext/html
dc.formattext/html
dc.languagespa
dc.languageeng
dc.publisherPontificia Universidad Católica de Chileen-US
dc.relationhttps://www.ricuc.cl/index.php/ric/article/view/540/pdf
dc.relationhttps://www.ricuc.cl/index.php/ric/article/view/540/pdf_1
dc.relationhttps://www.ricuc.cl/index.php/ric/article/view/540/html
dc.relationhttps://www.ricuc.cl/index.php/ric/article/view/540/html_1
dc.sourceRevista Ingeniería de Construcción; Vol 30, No 1 (2015); 39-52es-ES
dc.sourceRevista Ingeniería de Construcción; Vol 30, No 1 (2015); 39-52en-US
dc.source0718-5073
dc.source0716-2952
dc.subjectes-ES
dc.subjectAnálisis térmico; estructuras compuestas; ensayo push-out; conexiones tipo perno; incendioes-ES
dc.subjecten-US
dc.subjectThermal analysis; composite structures; push-out test; stud connections; fireen-US
dc.titleDiseño de conexiones tipo perno en vigas compuestas de acero y hormigón en situación de incendioes-ES
dc.titleDesign of stud connections in steel – concrete composite structures in fire situationen-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeen-US
dc.typeArtículo revisado por pareses-ES


This item appears in the following Collection(s)

Show simple item record