Influence of the column – beam resistant moment ratio on the collapse mechanism of a dual typology building located in a high seismic hazard zone
Influencia de la relación momento resistente columna – viga en el mecanismo de colapso de una edificación de tipología mixta ubicada en zona de alto peligro sísmico
Author
Gamoneda, Rodolfo
Sariol, José Alejandro
Martínez, Janet Otmara
Abstract
Compliance with the "strong column - weak beam" criterion in the structural design of buildings ensuresbetter behaviour of structures in seismic events. Design standards recommend an over-resistance factor ofbetween 1.2 and 1.4. The consideration of the Dynamic Soil-Structure Interaction DSI in the analysis modifies the collapse mechanism, so researchers recommend factors higher than 2. In the present research a nonlinear static analysis (pushover) is developed, using ETABS V19 software, of a 12-story reinforced concrete building with mixed typology, in which stiffness ratio values of 1.4, 2, 3 and 4 are used, and the influence of this parameter on the structural response of the building is determined. El cumplimiento del criterio “columna fuerte – viga débil” en la concepción estructural de edificaciones asegura un mejor comportamiento de las estructuras frente a eventos sísmicos. Las normas de diseño recomiendan un factor de sobrerresistencia de entre 1.2 y 1.4. La consideración de la Interacción Dinámica Suelo-Estructura IDSE en el análisis modifica el mecanismo de colapso por lo que investigadores recomiendan factores superiores a 2. En la presente investigación se desarrolla un análisis estático nolineal pushover, a través del software ETABS V19, de una edificación de 12 niveles de hormigón armado con tipología mixta, en la que se emplean valores de relación de rigidez de 1.4, 2, 3 y 4, y se determina la influencia de este parámetro en la respuesta estructural de la edificación.