Show simple item record

Normative Values for the Acoustic Speech Software Motor Speech Profile in Chilean spanish Speakers

dc.creatorPérez M., Hernán
dc.creatorFernández O., Rocío
dc.creatorOliva F., Carlos
dc.date2015-11-13
dc.date.accessioned2019-04-15T13:38:43Z
dc.date.available2019-04-15T13:38:43Z
dc.identifierhttps://revfono.uchile.cl/index.php/RCDF/article/view/37608
dc.identifier10.5354/rcdf.v14i0.37608
dc.identifier.urihttp://revistaschilenas.uchile.cl/handle/2250/31991
dc.descriptionEl objetivo de este artículo es exponer los resultados de un estudio normativo del rendimiento articulatorio de individuos chilenos normales, medido con los cinco parámetros que entrega el protocolo de rendimiento diadococinético del programa Motor Speech Profile de KayPentax. La intención es proporcionar a la comunidad fonoaudiológica valores de referencia de una muestra de hablantes del país para que puedan ser utilizados en la aplicación clínica y académica de este instrumento. Mediante el procedimiento de muestra espejo, se replica el estudio con el que se obtuvieron los valores de referencia originales del programa en una muestra de hablantes de inglés norteamericano. Además, se comparan ambos estudios con el propósito de determinar las diferencias y similitudes en el rendimiento de cada uno de los parámetros. Se concluye que tanto el DDKcvp como el DDKcvi manifiestan un comportamiento similar en ambos grupos y que el resto de los parámetros presenta ciertas diferencias. No obstante, en todos los parámetros es posible establecer un rango de variación que permite definir el comportamiento normal.es-ES
dc.descriptionThe present study aim to provide normative data of articulatory performance in normal Chilean individuals. The normative values obtained can serve as reference values from Chilean speakers which the speech-language pathology community can use in clinical and academic practice. The five parameters defined in the diadochokinetic protocol in the Motor Speech Profile of the KayPentax program were used. The method employed in the study which obtained the reference values from America English speakers was also adopted in this study. Furthermore, a comparison between the English and Spanish studies was carried out. DDKcvp and DDKcvi showed similar behavior in both groups. The other parameters presented some differences. However, a normal range for all parameters was possible to obtain. en-US
dc.formatapplication/pdf
dc.languagespa
dc.publisherUniversidad de Chile. Facultad de Medicina. Departamento de Fonoaudiologíaes-ES
dc.relationhttps://revfono.uchile.cl/index.php/RCDF/article/view/37608/39258
dc.sourceRevista Chilena de Fonoaudiología; Vol. 14 (2015): Noviembre; 4-14es-ES
dc.source0719-4692
dc.source0717-4659
dc.titleValores normativos para el programa de análisis acústico del habla Motor Speech Profile en hablantes de español de Chilees-ES
dc.titleNormative Values for the Acoustic Speech Software Motor Speech Profile in Chilean spanish Speakersen-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeArtículo revisado por pareses-ES


This item appears in the following Collection(s)

Show simple item record