Show simple item record

dc.contributoren-US
dc.creatorMarchant, Carlos
dc.creatorBrito, Daniela
dc.creatorDurán, Bruno
dc.creatorVidal, Juan Carlos
dc.creatorNavarrete, Ángel
dc.date2020-08-31
dc.date.accessioned2021-04-16T03:03:13Z
dc.date.available2021-04-16T03:03:13Z
dc.identifierhttps://revistas.uv.cl/index.php/asid/article/view/2416
dc.identifier10.22370/asd.2020.1.2.2416
dc.identifier.urihttps://revistaschilenas.uchile.cl/handle/2250/165578
dc.descriptionObjective: To evaluate the bond-strength (MPa) of an adhesive system to intracameral dentin after 2 different endodontic irrigation sequences.  Material and Methods: An in vitro double-blinded experimental cross-over study was conducted. 23 teeth were extracted, and sectioned, exposing the pulp chamber. Samples were separated into three groups: the first group (control) used a 0.9% saline solution; in the second group, the conventional sequence of irrigation of the University of Valparaíso was employed (5% NaOCl -18% EDTA-0.9% saline solution); and finally the third group, the experimental sequence was employed (5% NaOCl, 18% EDTA and 15% saline solution). The sealing technique was then conducted using universal 3M ESPE Single Bond adhesive and Filtek Z350 resin. Subsequently, the bond-strength test was performed in a microtensile, until fracture. Results: The control group had the highest values of frequency of adhesive and cohesive failure compared to the conventional and experimental group but presented a statistically non-significant association. As for the irrigation protocols, they did not show a major difference in their adhesive bond-strength when compared. Conclusion: The results of this study conclude that the adhesive resistance is not significantly modified by different irrigation protocols.en-US
dc.formatapplication/pdf
dc.languageeng
dc.publisherUniversidad de Valparaísoes-ES
dc.relationhttps://revistas.uv.cl/index.php/asid/article/view/2416/2407
dc.rightsCopyright (c) 2020 Applied Sciences in Dentistryes-ES
dc.rightshttp://creativecommons.org/licenses/by/4.0es-ES
dc.sourceApplied Sciences in Dentistry; Vol. 1, Núm. 2 (2020)en-US
dc.sourceApplied Sciences in Dentistry; Vol. 1, Núm. 2 (2020)es-ES
dc.source0719-5761
dc.source0719-5761
dc.subjectEndodontics; irrigators; coronal sealing; adhesive systems; hybrid layeren-US
dc.titleIN VITRO EVALUATION OF DENTINE ADHESIVE RESISTANCE AFTER APPLYING TWO IRRIGATION SEQUENCESen-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeen-US
dc.typees-ES


This item appears in the following Collection(s)

Show simple item record