dc.creator | Marchant, Carlos | |
dc.creator | Brito, Daniela | |
dc.creator | Durán, Bruno | |
dc.creator | Vidal, Juan Carlos | |
dc.creator | Navarrete, Ángel | |
dc.date | 2020-08-31 | |
dc.identifier | https://revistas.uv.cl/index.php/asid/article/view/2416 | |
dc.identifier | 10.22370/asd.2020.1.2.2416 | |
dc.description | Objective: To evaluate the bond-strength (MPa) of an adhesive system to intracameral dentin after 2 different endodontic irrigation sequences. Material and Methods: An in vitro double-blinded experimental cross-over study was conducted. 23 teeth were extracted, and sectioned, exposing the pulp chamber. Samples were separated into three groups: the first group (control) used a 0.9% saline solution; in the second group, the conventional sequence of irrigation of the University of Valparaíso was employed (5% NaOCl -18% EDTA-0.9% saline solution); and finally the third group, the experimental sequence was employed (5% NaOCl, 18% EDTA and 15% saline solution). The sealing technique was then conducted using universal 3M ESPE Single Bond adhesive and Filtek Z350 resin. Subsequently, the bond-strength test was performed in a microtensile, until fracture. Results: The control group had the highest values of frequency of adhesive and cohesive failure compared to the conventional and experimental group but presented a statistically non-significant association. As for the irrigation protocols, they did not show a major difference in their adhesive bond-strength when compared. Conclusion: The results of this study conclude that the adhesive resistance is not significantly modified by different irrigation protocols. | en-US |
dc.format | application/pdf | |
dc.language | eng | |
dc.publisher | Universidad de Valparaíso | es-ES |
dc.relation | https://revistas.uv.cl/index.php/asid/article/view/2416/2407 | |
dc.rights | Derechos de autor 2020 Applied Sciences in Dentistry | es-ES |
dc.source | Applied Sciences in Dentistry; Vol. 1 No. 2 (2020): Mayo-Agosto | en-US |
dc.source | Applied Sciences in Dentistry; Vol. 1 Núm. 2 (2020): Mayo-Agosto | es-ES |
dc.source | 0719-5761 | |
dc.source | 0719-5761 | |
dc.subject | Endodontics | en-US |
dc.subject | irrigators | en-US |
dc.subject | coronal sealing | en-US |
dc.subject | adhesive systems | en-US |
dc.subject | hybrid layer | en-US |
dc.title | IN VITRO EVALUATION OF DENTINE ADHESIVE RESISTANCE AFTER APPLYING TWO IRRIGATION SEQUENCES | en-US |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |